CHXCR - NITROGEN, PART A

Product Identification

Product ID:NITROGEN, PART A
MSDS Date:01/01/1995
FSC:6830
NIIN:01-331-9024
Status Code:A
Kit Part:Y
MSDS Number: CHXCR

Responsible Party
C F C RECLAIMATION AND RECYCLING SERVICE INC
318 N TREADAWAY
ABILENE, TX 79604
US

Emergency Phone: 915-675-5324

Info Phone: 915-675-5324

Cage: 0XXK5

Contractor
C F C RECLAIMATION AND RECYCLING SERVICE INC
560 ABILENE, TX 79604 US

Telephone: 915-675-5324

Cage: 0XXK5

Ingredients

NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

ACGIH TLV: ASPHYXIANT; 9596

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NITROGEN DEFINED AS SIMPLE
ASPHYXIANT.OXY LEVELS SHOULD BE MAINTAINED @>18MOLAR % @NORM ATM
PRESSURE(PO2>135TORR).NITROGEN IS NONTOXIC BUT LIBERATION OF LG AMT
IN CONF AREA COULD DISPLACE AMT OF OXY I N AIR NECESASRY TO SUPPORT
LIFE.
Explanation of Carcinogenicity:PER MSDSD:NO LISTED IN IARC/NTP/OSHA AS
CARC OR POTENTIAL CARC.
Effects of Overexposure:EFFECTS OF EXPO TO HI CONC SO AS TO DISPLACE
OXY IN AIR NECESASRY FOR LIFE MAY INCLUDE ANY,ALL OR NONE OF
FOLLOWING:LOSS OF BALANCE OR DIZZ;TIGHTNESS IN FRONTAL AREA OF
FOREHEAD;TINGLE OF TONGUE/FINGE RTIPS/TOES;WEAK SPEECH LEAD TO
INABILITYTO UTTER SOUNDS;RAPID REDUCTION IN ABILITY TO PERFORM
MOVEMENTS;REDUCED (SUPPL)
Medical Cond Aggravated by Exposure:PERSONS IN ILL HEALTH WHERE SUCH
ILLNESS WOULD BE AGGRAVATED BY EXPOSURE TO NITGROGEN SHOULD NOT BE
ALLOWED TO WORK W/OR HANDLE THIS PRODUCT.

First Aid

First Aid:PROMPT MED ATTN MANDATORY IN ALL CASES OF OVEREXPO TO
NITROGEN.RESCUE PERSONNEL SHOULD BE EQUIPPED W/SELF-CONTAINED
BREATH APPARATUS.INHAL:ASSIT TO UNCONTAM AREA,INHAL FRESH AIR.QUICK
REMOVAL MOST IMP ORTANT.UNCONSC GIVE ASSIST RESP/SUPPL OXY.FURTHER
TREATMENT SHOULD BE SYMPT/SUPP.

Fire Fighting

Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NON-FLAMMABLE, INERT GAS.
Fire Fighting Procedures:IF CYLINDERS ARE INVOLVED IN FIRE,SAFELY
RELOCATE OR KEEP COOL WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:EVACUATE ALL PERSONNEL FRM AFFECTED AREA.USE
APPROPRIATE PROTECTIVE EQPMT.LEADK IS IN CNTNR/CNTNR VALVE CONTACT
CLOSEST SUPPLIER LOCATION OR CALL EMERG TELEPHONE NO LISTED HEREIN.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY IN WELL VENTI AREA.VLAV PROT
CAPS MUST REMAIN IN PLACE UNLESS CYL SECURED W/VALVE OUTLET PIPE TO
USE PT.DONT DRAG,SLIDE,ROLL-USE HND TRUCK.
Other Precautions:USE PRESS RED REG WHEN CONNECT CYL TO LOWER
PRESS(<3000PSIG)PIP/SYST.DONT HEAT CYL TO INCR DISCHARGE RATE.USE
CHECK VALV/TRAP IN DISCHARGE LINE-PREVS HAZ BACKFLOW INTO CYL.STORE
IN COOL DRY WELL VENTI AREA AWAY FRM HEAV TRAF AREA/EMERG EXIT

Exposure Controls

Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:LOC EXHAU-TO PREVENT ACCUMULATION OF HI CONC SO AS TO
REDUCE OXYGEN LEVEL IN AIR TO LESS THAN 18MOLAR %.
Protective Gloves:ANY MATERIAL
Eye Protection:SAFETY GOGGLES OR GLASSES
Other Protective Equipment:SAFETY SHOES
Work Hygienic Practices:ADDN RECOMMENDATIONS:P-1,P-9,P-14,SAF BULLETIN
SB-2 FRM COMPRESS GAS ASSOC.
Supplemental Safety and Health
SIGN/SYMPT:CONSC OF SURROUNDINGS;LOSS OF TACTILE SENS;HEIGHTENED MENTAL
ACTIVITY.IT SHOULD BE RECOGNIZED THAT ITS POSSIBLE THAT NONE OF
ABOVE SYMPT MAY OCCUR IN GAS ASPHYXIA SO THAT THERE ARE NO DEFIN
ITE WARN SYMPT. NSN:MIXTURE OF NITROGEN& HYDROGEN SULFIDE,SEE
PNIND:B FOR HYDROGEN SULFIDE.

Chemical Properties

HCC:G3
Boiling Pt:B.P. Text:-320F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Decomp Temp:Decomp Text:NP
Vapor Pres:NP
Vapor Density:.0725LB/F3
Spec Gravity:0.97 @70F
pH:NP
Viscosity:NP
Evaporation Rate & Reference:N/A (GAS)
Solubility in Water:VERY SLIGHTLY
Appearance and Odor:COLORLESS, ODORLESS GAS
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
NONE.(NITROGEN IS NON-CORRO & MAY BE USED W/ANY COMMON STRUCTURAL
MATLS.)
Stability Condition to Avoid:NONE.PROTECT CYL FRM PHYS DMG.DONT ALLOW
TEMP OF STORAGE >125F/52C.STORE UPRIGHT/FIRMLY-PREVENT
FALL/KNOCKOVER.
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DONT ATTEMPT TO DIPSO WASTE/UNUSE QUANT.RETRN IN
SHIP CNTNR PROPERLY LABEL W/ANY VALVE OUTLET PLUG/CAP SECURED/VALVE
PROT CAP IN PLACE TO SUPPLIER.EMERG DISPO ASSIST CONTACT CLOSEST
SUPPLIER/CALL EMER G PHONE LISTED.SHOULDNT BE REFILL EXCEPTBY
QUALIF

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.